> Products > DC UPS > Giant 3-phase in 3-phase out Online UPS Giant 3-phase in 3-phase out Online UPS

Giant 3-phase in 3-phase out Online UPS Giant 3-phase in 3-phase out Online UPS

Brand : cassspower
Product origin : China
Delivery time : 15-30days
Supply capacity : 50k

• Online double-conversion • DSP technology guarantees high reliability • True galvanic isolation transformer design • Control designed to withstand all kinds of loads • Intelligent battery management to prolong battery lifecycle • Independent ventilation and redundant fan design enhance durable operation under harsh environment • Parallel operation with up to 4 units (option) • Variety of communication options available

CAPACITY

30 KVA / 24 KW

40 KVA / 32 KW

60 KVA / 48 KW

80 KVA / 64 KW

INPUT

Nominal Voltage

3 x 380VAC/400VAC (3Ph + N)

Acceptable Voltage Range

305VAC ~ 460VAC

Frequency

50/60 Hz ± 10 %

INVERTER

Nominal Voltage

3 x 380VAC/400VAC (3Ph + N)

Precision

Stationary: ±1% Transitory: ±5% (load variations 100-0-100%)

Frequency

50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz

Max. Synchronisation Speed

±1 Hz/s

Waveform

Pure Sinewave

Total Harmonic Distortion (THDv)

<2% (Linear Load) ; <5% (Non-linear Load)

Phase Displacement

120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load)

Dynamic Recovery Time

1 cycle at 98 % of the static value

Admissible Overload

110% for 10min,150% for 60s

Admissible Crest Factor

3:1

Admissible Power Factor

0.6~1 (inductive or capacitive)

Imbalance Output Voltage @ 100% Unbalanced Load

<1%

Current Limit

High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit

STATIC BYPASS

Type

Solid state

Voltage

3 x 380VAC/400VAC (3Ph + N)

Frequency

50/60 Hz

Activation Criterion

Microprocessor control

Transfer Time

Zero

Admissible Overload

150% for 1 hour, >180% for 30s

Transfer to Bypass

Immediate, for overloads above 160%

Retransfer

Automatic after alarm clear

MAINTENANCE BYPASS

Type

Without interruption

Voltage

3 x 400V (3Ph + N)

Frequency

50/60 Hz

Overall Efficiency

AC Mode

90%

Battery Mode

95%

BATTERY & CHARGER

Battery Type and Numbers

12V x 30 pcs, sealed lead acid battery

Nominal Battery Voltage

360 VDC

Charging Method

CC/CV

Precision

±1%

Charging Current

40 A

Charging Voltage

405 VDC

PHYSICAL

Dimensions, D x W x H(mm)

847.5 x 432.4 x 1134.5

1054 x 508 x 1287

Net Weight (Kgs)

271.5

298

462

532


specifications are subject to change without further notice